Corroseal® Rust Converting Primer
Product Data Sheet
Properties
| | | | | |
| VOC gr/L | 82.50 | Volume Solids ±2% | 31.30 | Odor | Mild |
| VOC lbs/G | 0.69 | Weight Solids ±2% | 38.90 | Thinning | DO NOT THIN. |
| |
| MPI # | | Theor. Spread Rate | 200.0 | Weight | 9.40 |
| Gloss 60° | | Wet Film Thickness | 8-10 mils | Viscosity | 300 cps |
| Sheen 85° | | Dry Film Thickness | | Resistance | |
| |
| Tinting Type | | Toxic Properties | | Cleanup | Soap and Water |
| Local Harvest | 34.9% WT | Light Reflectance | | Packaging | qts, one, five & drums |
| |
| pH | 3.0 | | | Flash Point | >200 F |
| |
| | | | | |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
Dry Times
Keep from freezing, Apply at 45 degrees F and rising and below 100 degrees F(7 degrees-37 degrees C) and falling. Test over zinc based coatings as some galvanizing reject Corroseal® chemistry. Do not apply onto zinc chromate or phosphates, lead, magnesium, copper powder, graphite, borate pigments. Chromate-treated (pickled) prefabricated steel building cold rolled perlins and gutters are to remain dry until top coated. Cold rolled steel can require abrading to anchor profile and degrease.
| | | | | |
| Dry To Touch | 30 Minutes | Dry To Sand | | Tack Free | |
| Dry To Recoat | | Dry To Topcoat | 24 hours minimum, up to 30 day | Dry To Hard | 40 - 60 minutes |
Prep & Prime
Remove all salt, loose rust, mill scale, dirt, grease, oil, old paint and other deposits. Apply non-solvent cleaner according to manufacturer's directions and rinse. A residue free surface is essential before coating application begins. The surface should be a CLEAN, TIGHT RUST.
Application
Brush, roll or spray undiluted Corroseal® in a heavy white coat with no surface show through at 8-10 mils wet film thickness. When black color appears, rust conversion has started. Wait at least 24 hours before top coating. A second coat of Corroseal® may be applied while first coat is still tacky. Apply all topcoats according to manufacturer’s specifications. Use oil based marine or industrial coatings for best weather protection. Use a separate container for application so you don't contaminate your original base product.
| |
| Coats | Waterbourne topcoats subject to tannin staining must be tested 48-60 hours before use. If tannin occurs, apply an oil based stain blocker or topcoat. Always prepare a test patch to ensure compatibility with substrate and subsequent products. |
| |
| |
| |
| |
| |
Corporate: 6107 N Marine Drive Portland, Oregon 97203 - Rodda Paint Co. - Regional: 3838 4th Avenue South Seattle, Washington 98134
Disclaimer - All technical advice, recommendations and services regarding this product are rendered by the Seller gratis. They are based on technical data which the Seller believes to be reliable and are intended for use by persons having skill and know-how, at their discretion and risk. Seller assumes no responsibility for results obtained or damages incurred from this product use by Buyer whether as recommended herein or otherwise. Such recommendations, technical advice or services are not to be taken as a license to operate under or suggest infringement of any patent.
Last Modification Date: 7/20/2011 - Please contact us at 800.452.2315 for additional information or questions