Properties
| | | | | |
| VOC gr/L | 211.00 | Volume Solids ±2% | 75.50 | Odor | Industrial paint thinner |
| VOC lbs/G | 1.76 | Weight Solids ±2% | 85.90 | Thinning | none recommended |
| |
| MPI # | 98 | Theor. Spread Rate | 220.0 | Weight | 12.47 |
| Gloss 60° | | Wet Film Thickness | 7 mils | Viscosity | 100 - 104 Krebs Units |
| Sheen 85° | | Dry Film Thickness | 5.5 mils | Resistance | excellent |
| |
| Tinting Type | Industrial | Toxic Properties | Non-toxic as dry film | Cleanup | 799398x Ropon Thinner |
| Local Harvest | | Light Reflectance | White 86%, less for tints | Packaging | gallons |
| |
| | | | | |
| |
| | | | | |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
Dry Times
At 77 degrees Fahrenheit and 50% Relative Humidity.
| | | | | |
| Dry To Touch | 2 hours | Dry To Sand | 16 hours | Tack Free | 2 hours |
| Dry To Recoat | 16 hours | Dry To Topcoat | 16 hours | Dry To Hard | 7 days |
Prep & Prime
Surfaces must be clean, dry and free of contaminants such as wax, oils, grease, weld splatter, or loose mil/scale/rust. As a minimum, SSPC-SPC Hand Tool Cleaning or SSPC-SPC3 Machine Tool Cleaning is recommended. Smooth surfaces should be abraded to enhance adhesion. Improved performance can be achieved with SSPC-SP6 Commercial Blast. All surfaces prepared for painting should be coated within 8 hours of completion of surface prep.
| |
| |
| Masonry | Ropon High Solids Epoxy may be used on masonry surfaces when surface is properly prepared. Consult Rodda Paint Co. for recommendations. |
| Metal | All surfaces to be painted must be clean, dry and maintained at 50 degrees Fahrenheit or greater throughout curing of the system. |
| Wallboard | Ropon High Solids Epoxy may be used on wallboard surfaces when surface is properly prepared. Consult Rodda Paint Co. for recommendations. |
| |
| |
Application
Do not apply when air or surface temperatures are expected to drop below 50 degrees F. or rise above 95 degrees F. during application and drying. Spray application recommended, may be brushed or rolled on small areas.
| |
| Coats | One or more depending on desired dry film thickness. |
| Brush | Small items may be brushed. Natural bristle 3 to 4 inch brush. Apply with full strokes. Avoid rebrushing until paint is dry. |
| Roller / Pad | Small areas, use top quality polyester cover. |
| Airless Spray | Recommended pressure 2000 to 2500 psi, using .013 to .017 tip orifice. |
| HVLP | Use approxiamately five pounds fluid and ten pounds atomizing air. |
| |
Corporate: 6107 N Marine Drive Portland, Oregon 97203 - Rodda Paint Co. - Regional: 3838 4th Avenue South Seattle, Washington 98134
Disclaimer - All technical advice, recommendations and services regarding this product are rendered by the Seller gratis. They are based on technical data which the Seller believes to be reliable and are intended for use by persons having skill and know-how, at their discretion and risk. Seller assumes no responsibility for results obtained or damages incurred from this product use by Buyer whether as recommended herein or otherwise. Such recommendations, technical advice or services are not to be taken as a license to operate under or suggest infringement of any patent.