Surfbond II
Product Data Sheet
Properties
| | | | | |
| VOC gr/L | 67.00 | Volume Solids ±2% | 27.00 | Odor | mild of latex emulsion |
| VOC lbs/G | 0.56 | Weight Solids ±2% | 36.00 | Thinning | none recommended |
| |
| MPI # | | Theor. Spread Rate | 440.0 | Weight | 9.50 |
| Gloss 60° | 5-10 | Wet Film Thickness | | Viscosity | 68 - 72 Krebs Units |
| Sheen 85° | | Dry Film Thickness | Not to exceed 1.0 DFT | Resistance | excellent when topcoated |
| |
| Tinting Type | Universal | Toxic Properties | Non-toxic as dry film | Cleanup | warm soapy water |
| Local Harvest | 37% | Light Reflectance | Not applicable | Packaging | single & five gallons |
| |
| | | | | |
| |
| | | | | |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
Dry Times
At 77 degrees Fahrenheit and 50% Relative Humidity.
| | | | | |
| Dry To Touch | 1-2 hrs, w/ substate porosity | Dry To Sand | N/A | Tack Free | 1-2 hours |
| Dry To Recoat | 4 hours | Dry To Topcoat | 4 hours | Dry To Hard | N/A |
Prep & Prime
Surfaces to be coated must be free of dirt, oil, mildew, excessive chalk and other foreign matter. Remove loose paint and patch holes or cracks. Prime bare surfaces, dull or prime glossy surfaces, and then scuff sand using 80 to 100 grit sandpdaper on a hand sander. Remove all sanding dust.
| |
| |
| Masonry | Surface to be coated should be clean and dry. Surface must be free of all dirt, grease, efflorescence form treatments, curing compounds and laitance. New concrete should be allowed to cure. On high pH substrates a test patch is recommended. |
| |
| |
| |
| |
Application
Do not apply when air or surface temperatures are expected to drop below 50 Deg. F. or rise above 95 Deg F. during application and drying. Please see expected dry times.
| |
| |
| Brush | A nylon/polyester brush is recommended for this project. |
| Roller / Pad | Use 1/4" to 3/8" nap synthetic or lambswool roller cover. Use a synthetic pad. |
| Airless Spray | Recommended pressure 2000 to 2500 psi, using .015 to .021 tip orifice. |
| HVLP | Reduce up to one pint per gallon with water. Accuspray 24K. |
| Conventional Spray | Reduce up to one pint per gallon with water. Recommended air pressure 40-60 psi; fluid pressure 20 psi; tip size .0042" to .0045" with matching cap. |
Corporate: 6107 N Marine Drive Portland, Oregon 97203 - Rodda Paint Co. - Regional: 3838 4th Avenue South Seattle, Washington 98134
Disclaimer - All technical advice, recommendations and services regarding this product are rendered by the Seller gratis. They are based on technical data which the Seller believes to be reliable and are intended for use by persons having skill and know-how, at their discretion and risk. Seller assumes no responsibility for results obtained or damages incurred from this product use by Buyer whether as recommended herein or otherwise. Such recommendations, technical advice or services are not to be taken as a license to operate under or suggest infringement of any patent.
Last Modification Date: 8/5/2011 - Please contact us at 800.452.2315 for additional information or questions